In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

Use of the Heartrail II catheter as a distal stent delivery device; an extended case series.

Mamas, Mamas A; Eichhoefer, Jonas; Hendry, Cara; El-Omar, Magdi; Clarke, Bernard; Neyses, Ludwig; Fath-Ordoubadi, Farzin; Fraser, Doug

EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2009;5(2):265-71.

Access to files

Full-text and supplementary files are not available from Manchester eScholar. Full-text is available externally using the following links:

Full-text held externally

Abstract

Aims: The Terumo Heartrail catheter (Terumo Corp., Tokyo, Japan) allows extra deep catheter intubation of coronary vessels and has been shown to be useful in CTO lesions. The aim of this study is to assess the safety and efficacy of using the Heartrail II catheter as a distal stent delivery system in PCI following failure of conventional techniques.Methods and results: We prospectively identified cases performed over a 15-month period in which a Heartrail catheter was used to facilitate stent delivery following failure of conventional techniques. Stent delivery using the Heartrail catheter was performed in 35 cases and was successful in 31 cases. Success rates of 100% in grafts, 95% in RCA, 80% in LAD and 60% in circumflex cases were recorded respectively. Successful stent delivery was associated with intubation depth, with 29/29 succeeding when the intubation depth was > 2 cm and failure in 4/5 cases when the intubation depth </= 2 cm. There were no complications related to deep intubation of the catheter. Conclusions: Use of the Heartrail catheter is safe and highly effective for aiding stent delivery across proximal obstructions in both left and right coronary systems. The small number of unsuccessful cases were related to inability of the catheter to traverse stenotic proximal obstructions within 2 cm of the RCA and LCA origins.

Bibliographic metadata

Content type:
Published date:
Language:
eng
Abbreviated journal title:
ISSN:
Place of publication:
France
Volume:
5
Issue:
2
Pagination:
265-71
Digital Object Identifier:
10.4244/EIJV5I2A41
Pubmed Identifier:
19527983
Pii Identifier:
EIJV5I2A41
Access state:
Active

Institutional metadata

University researcher(s):

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:77768
Created by:
Neyses, Ludwig
Created:
15th March, 2010, 13:20:26
Last modified by:
Neyses, Ludwig
Last modified:
10th April, 2013, 21:44:36

Can we help?

The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.