In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

Detection of osteoporosis by dual energy X-ray absorptiometry (DXA) of the calcaneus: is the WHO criterion applicable?

PachecoE.M, Harrison EJ, Ward KA, Lunt M, AdamsJ.E

Calcified Tissue International. 2002;70, 6:475-482.

Access to files

Full-text and supplementary files are not available from Manchester eScholar. Full-text is available externally using the following links:

Full-text held externally

Abstract

The study assessed the precision, sensitivity, and specificity of a recently developed peripheral dual-energy X-ray absorptiometry (DXA) scanner, applied to the calcaneus, in the identification of individuals with osteoporosis at axial sites by DXA. Two hundred and two women, aged 55.2 +/- l3.7 years (mean +/- SD), participated in the study. The precisions (coefficient of variation) of measurements in vitro (0.48%) and in vivo (1.40%) were very good. The in vivo precision was independent of the operator, foot size, foot width, weight, height, and body mass index. Calcaneus BMD correlated moderately (r = 0.494-0.690, P <0.001) with axial BMD measurements by DXA. Using the World Health Organization (WHO) criterion for defining osteoporosis (T score ? -2.5) the specificity of the calcaneus to identify patients with osteoporosis at total hip, femoral neck, spine, or any of these axial sites was excellent (97.0%, 97.0%, 96.5%, and 97.1%, respectively); however, the sensitivity was poor (58.8%, 36.4%, 21.8%, and 20.3%, respectively). Therefore, the WHO criterion is not appropriate for DXA calcaneus. Based on femoral neck BMD for detection of osteoporosis, a more appropriate calcaneus T score threshold would be -1.4 by analyses of receiver-operator characteristic curves; this might serve to select those patients who might appropriately be referred for axial DXA

Bibliographic metadata

Type of resource:
Content type:
Publication type:
Publication form:
Published date:
Volume:
70, 6
Start page:
475
End page:
482
Pagination:
475-482
Digital Object Identifier:
10.1007/s002230020030
General notes:
  • UI - 22144036DA - 20020731IS - 0171-967XLA - engPT - Evaluation StudiesPT - Journal ArticleSB - IM
Access state:
Active

Institutional metadata

University researcher(s):

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:1d5631
Created:
28th August, 2009, 23:14:07
Last modified:
15th November, 2012, 01:53:31

Can we help?

The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.