In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

Lack of agreement between rheumatologists in defining digital ulceration in systemic sclerosis

Herrick AL, Roberts C, Tracey A, Silman A, Anderson M, Goodfield M, McHugh N, Muir L, Denton C

Arthritis & Rheumatism. 2009;60(3):878-82.

Access to files

Full-text and supplementary files are not available from Manchester eScholar. Full-text is available externally using the following links:

Full-text held externally

Abstract

OBJECTIVE: To test the intra- and interobserver variability, among clinicians with an interest in systemic sclerosis (SSc), in defining digital ulcers. METHODS: Thirty-five images of finger lesions, incorporating a wide range of abnormalities at different sites, were duplicated, yielding a data set of 70 images. Physicians with an interest in SSc were invited to take part in the Web-based study, which involved looking through the images in a random sequence. The sequence differed for individual participants and prevented cross-checking with previous images. Participants were asked to grade each image as depicting "ulcer" or "no ulcer," and if "ulcer," then either "inactive" or "active." Images of a range of exemplar lesions were available for reference purposes while participants viewed the test images. Intrarater reliability was assessed using a weighted kappa coefficient with quadratic weights. Interrater reliability was estimated using a multirater weighted kappa coefficient. RESULTS: Fifty individuals (most of them rheumatologists) from 15 countries participated in the study. There was a high level of intrarater reliability, with a mean weighted kappa value of 0.81 (95% confidence interval [95% CI] 0.77, 0.84). Interrater reliability was poorer (weighted kappa = 0.46 [95% CI 0.35, 0.57]). CONCLUSION: The poor interrater reliability suggests that if digital ulceration is to be used as an end point in multicenter clinical trials of SSc, then strict definitions must be developed. The present investigation also demonstrates the feasibility of Web-based studies, for which large numbers of participants can be recruited over a short time frame.

Bibliographic metadata

Type of resource:
Content type:
Publication type:
Publication form:
Published date:
Journal title:
ISSN:
Publisher:
Place of publication:
United States
Volume:
60
Issue:
3
Start page:
878
End page:
82
Total:
-795
Pagination:
878-82
Digital Object Identifier:
10.1002/art.24333
Access state:
Active

Institutional metadata

University researcher(s):

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:1d19119
Created:
30th August, 2009, 15:09:52
Last modified:
29th January, 2015, 09:02:31

Can we help?

The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.