In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

Use of electromagnetic induction tomography for monitoring liquid metal/gas flow regimes on a model of an industrial steel caster

N Terzija, W Yin, G Gerbeth, F Stefani, K Timmel, T Wondrak and A J Peyton

Measurement Science and Technology. 2011;22(1):015501.

Access to files

Full-text and supplementary files are not available from Manchester eScholar. Full-text is available externally using the following links:

Full-text held externally

Abstract

Monitoring of the steel flow through the submerged entry nozzle (SEN) during continuous casting presents a challenge for the instrumentation system because of the high temperature environment and the limited access to the nozzle in between the tundish and the mould. Electromagnetic inductance tomography (EMT) presents an attractive tool to visualize the steel flow profile within the SEN. In this paper, we investigate various flow regimes over a range of stopper positions and gas volume flow rates on a model of a submerged entry nozzle. A scaled (approximately 10:1) experimental rig consisting of a tundish, stopper rod, nozzle and mould was used. Argon gas was injected through the centre of the stopper rod and the behaviour of the two-phase GaInSn/argon flow was studied. The experiments were performed with GaInSn as an analogue for liquid steel, because it has similar conductive properties as molten steel and allows measurements at room temperature. The electromagnetic system used in our experiments to monitor the behaviour of the two-phase GaInSn/argon flow consisted of an array of eight equally spaced induction coils arranged around the object, a data acquisition system and a host computer. The present system operates with a sinusoidal excitation waveform with a frequency of 40 kHz and the system has a capture rate of 40 frames per second. The results show the ability of the system to distinguish the different flow regimes and to detect the individual bubbles. Sample tomographic images given in the paper clearly illustrate the different flow regimes.

Bibliographic metadata

Type of resource:
Content type:
Publication type:
Publication form:
Published date:
Volume:
22
Issue:
1
Start page:
015501
Total:
8
Digital Object Identifier:
10.1088/0957-0233/22/1/015501
Access state:
Active

Institutional metadata

University researcher(s):

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:142446
Created by:
Peyton, Anthony
Created:
22nd December, 2011, 10:05:59
Last modified by:
Peyton, Anthony
Last modified:
11th March, 2014, 19:33:12

Can we help?

The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.